From 1 January 2027, every home in Queensland needs interconnected photoelectric smoke alarms. That covers houses, townhouses and units that people own and live in, not only rentals and homes being sold.
Landlords and sellers have had to meet these rules since 2022. The 2027 change brings in everyone else. If you’ve lived in the same house for years and never had a reason to look closely at your smoke alarms, this is the deadline that applies to you.
For most older homes, getting compliant means a few new alarms in the right rooms, all linked together. This guide covers what the law asks for, where the alarms go, who can fit them and what the job usually involves.
What the 2027 Smoke Alarm Laws Require
By 1 January 2027, the smoke alarms in every Queensland home must be:
- Photoelectric, marked to Australian Standard AS 3786-2014, with no ionisation sensor
- Interconnected, so every alarm sounds when one is triggered
- Hardwired to the mains, or powered by a sealed 10 year battery
- Less than 10 years old
- Installed in every bedroom, in hallways that connect bedrooms to the rest of the home, and on every storey
Registered caravans and motorhomes are also covered from the same date. The Queensland Fire Department sets out the full requirements if you want the official detail.
Why Queensland Changed the Rules
In 2011, a house fire at Slacks Creek in Logan killed 11 people, eight of them children. The state rewrote its smoke alarm laws in response and gave households ten years to catch up, rolling the changes out in three stages.
How the Rollout Has Worked
- 1 January 2017: new homes and major renovations needed interconnected photoelectric alarms.
- 1 January 2022: any home sold or leased, including a lease renewal, had to meet the standard first.
- 1 January 2027: every remaining home has to comply, whether it’s sold, rented or neither.
What Counts as a Compliant Smoke Alarm
A smoke alarm can work and still not comply. Pressing the test button tells you it beeps, not that it meets the 2027 rules. There are four things to check.
Photoelectric, Not Ionisation
Photoelectric alarms use a light sensor to pick up visible smoke. That makes them quicker on slow, smouldering fires, the kind that can build for a long time overnight before there’s much flame. Ionisation alarms are slower to pick those fires up, and the Queensland Fire Department advises replacing them even if they still work.
The label usually tells you which type you have. A compliant alarm says photoelectric and carries the AS 3786-2014 marking. Ionisation alarms often have a small radiation symbol on them.
Interconnected, by Wire or Wireless
Interconnected alarms talk to each other. Smoke in the garage sets off the alarm in the main bedroom, so everyone hears it wherever the fire starts.
The link can be a cable run between the alarms or a wireless signal. Wired interconnection suits new builds and homes being rewired. In an existing home, wireless is usually the practical choice because nothing needs to be cabled through the ceiling.
Hardwired or a Sealed 10 Year Battery
Each alarm has to run on 240 volt mains power or a non removable 10 year battery. The old style with a 9 volt battery you change every year no longer meets the rules.
There’s one catch. If your home already has hardwired alarms, the replacements have to be hardwired as well. You can’t swap a mains powered alarm for a battery one.
Less Than 10 Years Old
Smoke alarm sensors wear out, so any alarm older than ten years has to be replaced, even if it still sounds on test. The manufacture or expiry date is normally printed on the back of the alarm.
Where Smoke Alarms Must Be Installed
On every storey of the home, you need a smoke alarm:
- In every bedroom
- In each hallway that connects bedrooms to the rest of the home
- Between the bedrooms and the rest of the storey, if there’s no hallway
- In the most likely path out of the home, on any storey with no bedrooms
The last point is easy to miss in two storey homes. A downstairs level with a rumpus room, laundry and garage but no bedrooms still needs its own alarm.
As a rough guide, a single storey home with three bedrooms and one hallway needs four alarms. Add another bedroom, a second hallway or another level and the number goes up from there.
Placement on the Ceiling
Alarms go on the ceiling, ideally near the middle of the room. The Queensland Fire Department sets minimum clearances:
- At least 300mm from corners and light fittings
- At least 400mm from anything that moves air, such as an air conditioner or the tip of a ceiling fan blade
Sloping ceilings and exposed beams have their own requirements. Keeping alarms back from the kitchen and bathroom also helps, so cooking and shower steam don’t set them off for no reason.
Does the 2027 Deadline Apply to You?
If You Own and Live in Your Home
This is who the 2027 deadline is for. From 1 January 2027, your home needs to meet the same standard as a rental, with no sale or new lease needed to trigger it. You don’t need to notify the Queensland Fire Department once the work is done.
If You Rent Your Property Out
Your obligations started in 2022. As well as having compliant alarms installed, you need to test every alarm within 30 days before a tenancy starts, and that includes renewals. During the tenancy, the tenant tests each alarm at least once every 12 months.
If You’re Selling
Homes sold since 2022 have had to meet the standard, and the seller declares it on the Form 24 that’s lodged with the property transfer. Sorting the alarms before you list means they won’t hold anything up once you have a buyer.
What Happens If You Don’t Comply
The laws carry fines for non compliance. In practice, the alarms tend to get looked at when something else happens, such as a sale, a new lease or a fire. If you’re unsure how non compliant alarms affect your home insurance, ask your insurer directly.
Who Can Install Smoke Alarms in Queensland
Sealed 10 year battery alarms don’t need an electrician, so you can fit those yourself. Anything connected to 240 volt mains power has to be installed by a licensed electrician. Because hardwired alarms must be replaced with hardwired alarms, most homes that already have them will need one.
Testing is a different matter. You can test your own alarms with the test button, no technician needed. Queensland’s Office of Fair Trading says it’s illegal for a trader to tell you otherwise, or to pressure you into paying for an upgrade on the spot. Before you book anyone, you can check their licence on the WorkSafe Queensland electrical licence search.
Hardwired Alarms That Go Off for No Reason
False alarms on a hardwired system can come from the power side rather than the alarm itself. Power fluctuations on the supply, including from solar, can set them off. So can alarms wired onto a lighting circuit with a dimmer. A filter fitted at the switchboard can help, so if your alarms sound at random, have the switchboard and circuits checked as part of the upgrade.
What a Smoke Alarm Upgrade Involves
It starts with a licensed electrician walking through the house, checking your existing alarms against the four requirements and counting the bedrooms, hallways and storeys. You then get a quote for exactly what the house needs.
For most existing homes the work is done in one visit. The old alarms come down, the new ones go up, and every alarm is linked and tested together before we leave.
Our smoke alarm installation covers Voltex and Cavius photoelectric alarms, supplied, fitted and certified. Pricing is $140 to $165 + GST per alarm supplied and installed, and the compliance certificate on a new install is $99 + GST. For a four alarm home, that’s roughly $560 to $660 + GST before the certificate.
Why It’s Worth Booking Early
The deadline doesn’t move, and every home that hasn’t been upgraded is working towards the same date. Electricians get busier as it gets closer, and the Christmas break takes a few weeks out of the calendar right before it, so booking in early gives you the widest choice of times.
Get Your Smoke Alarms Checked
Southampton Electrical is a family run business, and every job is done by a licensed electrician (ECL 91128). As Moreton Bay electricians, we work across Brisbane’s northside and out to Redcliffe.
We’ll check what you’ve already got, tell you plainly what the house needs to comply, and give you a free quote.
Frequently Asked Questions
Do units and townhouses have to comply?
Yes. The 2027 deadline covers existing houses, townhouses and units, as well as manufactured homes. Each dwelling needs its own interconnected alarms in the required locations.
Do I need a smoke alarm compliance certificate?
Owner occupiers don’t need to lodge one with anyone. Some real estate agents ask for a certificate when a home is sold or leased, and it’s a handy record that the work has been done properly.
How often should I test my smoke alarms?
The Queensland Fire Department recommends testing them once a month with the test button. Clean off dust and insects with a vacuum, and never paint over or cover an alarm.